Choosing a capsule separating machine starts with the recovery task, not the largest advertised capacity.
The right equipment should process your actual capsule formats, collect the contents acceptably, fit the available workspace, and support a practical cleaning routine.
For manufacturers comparing the URMACHINE NQF-400B, NQF-600B, and NQF-800B, the main published differences are processing capacity, power, dimensions, and weight. The final choice should also consider demonstrated material behavior and total batch completion time.
Start by Defining the Application
Describe exactly what the machine must do.
For capsule recovery, the task is to open filled two-piece hard capsules and collect the contents separately from the shells.
If defective-capsule detection and rejection are also required, list that function separately. Define the defects to be detected, the acceptance criteria, and how rejected capsules will be handled.
Do not assume that a general rejection function covers every possible weight, visual, closure, or contamination defect.
Also establish whether the input material is eligible for recovery. Equipment selection cannot resolve an unexplained material-quality problem.
Compare the Three NQF Models
| Specification | NQF-400B | NQF-600B | NQF-800B |
|---|---|---|---|
| Listed processing capacity | 200–400 capsules/min | 400–600 capsules/min | 600–800 capsules/min |
| Supported capsule sizes | 000#–5# | 000#–5# | 000#–5# |
| Mold / format replacement | Not required | Not required | Not required |
| Listed power supply | 220V, 50Hz | 220V, 50Hz | 220V, 50Hz |
| Listed machine power | 0.18 kW | 0.18 kW | 0.38 kW |
| Listed dimensions | 500 × 600 × 1200 mm | 500 × 600 × 1200 mm | 500 × 700 × 1200 mm |
| Listed net weight | 105 kg | 115 kg | 115 kg |
The listed power relates to the machine specification. Confirm the complete installed utility requirement, including any external equipment.
Capsule-size coverage does not automatically establish suitability for every shell material, locking condition, sealed capsule, or formulation.
Choose Capacity from the Available Batch Window
Determine the quantity requiring recovery and how much time is available.
When to Evaluate NQF-400B
Start with the NQF-400B capsule separator when its listed 200–400 capsules-per-minute range fits the expected workload.
When to Evaluate NQF-600B
Consider the NQF-600B capsule separator when the recovery schedule calls for a listed range of 400–600 capsules per minute.
When to Evaluate NQF-800B
Review the NQF-800B capsule separator when higher processing capacity is needed within a shorter available window. The 800B also has a larger listed base dimension and higher machine power than the other two models.
These are selection starting points. A representative trial should establish the usable operating rate.
Confirm the Actual Capsule and Fill
Provide capsule samples and a written application description. Include:
- Capsule size and shell material.
- Locking condition.
- Any banding or sealing.
- Typical shell damage.
- Powder, granule, or pellet characteristics.
- Approximate contents mass.
- Reason for rejection.
- Typical and maximum batch quantity.
Changing sizes without replacing parts is convenient, but it does not eliminate the need to establish suitable settings. For adhesive powders or sensitive pellets, pay particular attention to retention and material condition after separation.
Evaluate Recovery Performance Separately from Opening Speed
A machine can open capsules quickly while collecting an unacceptable material stream. Agree on trial measures before testing:
| Measure | Purpose |
|---|---|
| Capsules opened | Evaluate opening performance |
| Unopened capsules | Identify incomplete processing |
| Collected contents mass | Quantify physical collection |
| Powder remaining in shells | Assess discharge losses |
| Shell carryover | Evaluate separation quality |
| Equipment retention | Assess hold-up and cleaning losses |
| Relevant material attributes | Assess suitability for intended use |
| Total task time | Evaluate the practical workflow |
Define the measurement basis for each percentage. Different denominators can make apparently similar recovery claims impossible to compare.
Check Cleaning, Changeover & Installation Space
Ask to see the machine opened for inspection. Review the hopper, opening mechanism, product passages, screens, collection interfaces, and seals included in the proposed configuration. Find out:
- Which components contact the product.
- Which parts can be removed.
- Whether tools are required.
- Where material can accumulate.
- How parts are cleaned and dried.
- How correct reassembly is checked.
- How long cleaning takes for a representative product.
For short recovery batches, cleaning effort can have a greater effect on total productivity than the difference between two operating speeds.
The machine’s external dimensions are only part of the space requirement. Allow for:
- Capsule loading access.
- Output containers.
- Access for inspection and maintenance.
- Removal of parts during cleaning.
- Utility connections.
- Any extraction or collection accessories.
- Safe operator movement.
A compact machine still requires a workable operating area around it. Confirm the overall installed arrangement before finalizing the room layout.
Request a Sample Trial and Demonstration
URMACHINE offers product testing and video confirmation before shipment. Use this process to evaluate the proposed separator with representative capsules. Agree on the trial scope:
- Identify the input material.
- Record the quantity or mass.
- Confirm the machine and settings.
- Observe feeding and opening.
- Inspect collected contents and shells.
- Record unopened capsules and losses.
- Review handling and cleaning time.
A test video is most useful when accompanied by measured results. Do not use nominal filling weight as the starting contents mass without checking whether it represents the rejected capsules.
Review Support, Commercial Scope & Technical Enquiry
Discuss the operating manual, training, installation assistance, spare parts, warranty, and technical-support arrangements before ordering.
URMACHINE’s published service information includes English manuals, video guidance, remote assistance, and a 12-month warranty. Confirm the applicable terms and included services in the quotation and purchase agreement. Also clarify whether the supply includes:
- Collection containers.
- Screens or separation accessories.
- Vacuum or extraction equipment.
- Connection components.
- Initial spare parts.
- Trial documentation.
A complete supply-scope comparison is more useful than comparing the machine price alone.
A useful enquiry can be brief:
Add the rejection criteria separately if detection and rejection form part of the project.
Frequently Asked Questions
Do I need different molds for every capsule size?
The NQF series supports capsule sizes 000#–5# without replacing molds or format parts. Confirm the operating adjustments for each application.
Which model should I buy for 24,000 capsules?
The answer depends on the available processing window, cleaning time, frequency, and demonstrated operating rate. Batch quantity alone is insufficient.
Is the listed machine power the complete installation requirement?
Not necessarily. Confirm the requirements of any external extraction, air, vacuum, or collection equipment.
What is the most useful acceptance test?
A representative material trial with agreed input and output measurements, collected-material inspection, timing, and a cleaning demonstration.
Choose on Demonstrated Fit with URMACHINE
The NQF-400B, NQF-600B, and NQF-800B provide different capacity options within the URMACHINE range. Select the model that meets the required batch window while delivering acceptable opening, collection, cleaning, and handling performance.