ELECTRONIC COUNTING EQUIPMENT | URMACHINE

Capsule Counting Machine for Tablets, Pills & Softgels

Compare electronic capsule and tablet counting machines for pharmaceutical and supplement bottling. Learn how to evaluate real bottle output, counting performance and machine suitability before requesting a quotation.

A capsule and tablet counting machine separates solid-dose products, detects individual pieces and dispenses a preset quantity into containers. URMACHINE supplies semi-automatic counters and URGC-S automatic counting systems for compatible capsules, tablets, softgels and pills.

  • Understand electronic counting and bottle output
  • Compare semi-automatic and automatic equipment
  • Review eight URGC machine models and technical data
  • Plan testing and a complete bottle packaging line
URMACHINE Electronic Capsule & Tablet Counter
2 Series
Semi-automatic and automatic
8 Models
Models in supplied range
10–120
Bottles/min: URGC-S model ranges
2–9999
Adjustable count per bottle: URGC-S
01 / EQUIPMENT FUNDAMENTALS

What Is a Capsule Counting Machine?

A capsule counting machine is packaging equipment used to count a specified number of individual capsules or other compatible solid-dose products. In bottle packaging, it works between empty-bottle handling and downstream processes such as desiccant insertion, capping and labeling.

In electronic counting equipment, products are guided along feeding channels and detected by sensors. The controller tracks the quantity and coordinates product discharge. Semi-automatic machines require greater operator participation; automatic models are designed to coordinate counting with bottle movement.

Machine suitability is not determined by the product name alone. Capsule size, tablet shape, dust, product flow, count per bottle and desired bottles per minute all affect the correct equipment choice.

Electronic Capsule and Tablet Counting Process Illustration

Where Are Capsule and Tablet Counters Used?

01

Pharmaceutical Packaging

Counting compatible hard capsules, plain tablets and coated tablets into bottles for downstream packaging operations.

02

Nutraceutical Packaging

Counting selected supplement capsules, softgels and tablets where their shape and surface characteristics suit the feeder.

03

Contract Packaging

Projects involving different product types and bottle counts, with changeover requirements that should be evaluated before selection.

04 / EQUIPMENT RANGE

Explore URMACHINE Capsule & Tablet Counting Machines

Review two semi-automatic models and six URGC-S automatic models. Use the specification tables below for initial selection, then confirm actual product and bottle compatibility.

Semi-Automatic Counting Machines

URGC-6BS 4-Channel Electronic Tablet and Capsule Counter
2,000–3,000 pcs/min
6BS

Operator-assisted counting machine for compatible capsules, tablets and selected pill products.

  • Dimensions: 550 × 280 × 850 mm
  • Net weight: 50 kg
  • Brochure power: 0.1 kW
Request 6BS Quote →
URGC-2B 2-Head Semi-Automatic Counting Machine
800–2,000 capsules/min
2BS

Compact semi-automatic counter for selected capsule, tablet and softgel bottle-counting applications.

  • Dimensions: 735 × 580 × 720 mm
  • Net weight: 50 kg
  • Brochure power: 100 W
Request 2BS Quote →

Semi-Automatic Model Comparison

Parameter6BS2BS
Rated speed2,000–3,000 pcs/min800–2,000 capsules/min
Bottle type10–500 ml round or square plastic bottles10–500 ml round or square plastic bottles
ApplicationsCapsules #00–#5, softgels, tablets and selected pillsHard capsules, softgels, tablets and pills
Accuracy (expressed in sheet)>99.5%±0.3%
Power0.1 kW220V / 50–60Hz / 100 W
Dimensions (mm)550 × 280 × 850735 × 580 × 720
Weight50 kg50 kg

URGC-S Series Automatic Counting Machines

Six models cover different nominal bottle output ranges. The count setting and actual bottle rate should be evaluated together with the product and bottle configuration.

URGC-8S Automatic Tablet & Capsule Counting Machine
10–40 bottles/min
URGC-8S

Entry model within the listed automatic counting series.

Request Quote →
URGC-12S Automatic Electronic Counting Machine
10–50 bottles/min
URGC-12S

Automatic electronic counting for selected bottle line applications.

Request Quote →
URGC-16S 16-Channel Electronic Tablet and Capsule Counter
10–70 bottles/min
URGC-16S

Intermediate model for higher nominal bottle output requirements.

Request Quote →
URGC-24S High Speed Automatic Capsule Counter
10–80 bottles/min
URGC-24S

Automatic counter for selected integrated packaging lines.

Request Quote →
URGC-32S Industrial Tablet Counter
10–100 bottles/min
URGC-32S

Higher nominal throughput for suitable product and bottle formats.

Request Quote →
URGC-48S High Capacity Tablet & Capsule Counter
10–120 bottles/min
URGC-48S

Highest listed nominal bottle output in the supplied URGC-S range.

Request Quote →

URGC-S Series Technical Specifications

Parameter8S12S16S24S32S48S
Output (bottles/min)10–4010–5010–7010–8010–10010–120
Count setting / bottle2–9999 (adjustable; verify application)
Power supply220V / 50Hz (brochure)
Power (kW)0.60.750.81.01.31.6
Filling error expression≤2‰ bottles (test definition to be confirmed)
Material304SS + 316SS (specific contact surfaces to be confirmed)
Dimensions (mm)1360 × 1500 × 17001360 × 1500 × 17001660 × 1500 × 17001660 × 1600 × 17002510 × 1600 × 17002510 × 1600 × 1700
Weight (kg)520540400550710800
Technical-data notice: Values above are transcribed from the supplied product-sheet images shared during page planning. Confirm the latest datasheet, the test definitions and the exact configuration before publishing contractual specifications. Nominal output is not a guarantee of throughput with every product.

Which URGC model fits your project?

Share your product size, count per bottle, bottle opening and desired bottles/minute. We can help narrow down the model range and discuss testing.

Request a Model Recommendation →
03 / MACHINE TYPES

Types of Capsule and Tablet Counting Machines

The main choice for this URMACHINE product range is between operator-assisted semi-automatic counters and automatic electronic bottle counters.

OPERATOR ASSISTED COUNTING

Semi-Automatic Counting Machines

Semi-automatic equipment is useful when bottle handling and the production process can include more operator participation. It can suit selected standalone or smaller-scale packaging arrangements.

  • URGC-6BS and URGC-2B in the supplied range
  • Capacity described as pieces or capsules per minute
  • Check operator workflow and actual bottle throughput
AUTOMATED BOTTLE COUNTING

Automatic Electronic Counting Machines

Automatic counters coordinate product detection with bottle positioning and discharge. They are generally selected where consistent bottle output and integration with other packaging stations are priorities.

  • URGC-8S through URGC-48S in the supplied range
  • Capacity described as bottles per minute
  • Can be planned with capping, sealing and labeling

Semi-Automatic vs. Automatic Counting Machines

Selection FactorSemi-AutomaticAutomatic
Typical operator involvementMore direct handling and supervisionMore automated bottle transfer and counting cycle
URMACHINE modelsURGC-6BS / URGC-2BURGC-8S / 12S / 16S / 24S / 32S / 48S
Brochure speed unitpcs/min or capsules/minbottles/min
Line integrationCheck standalone workflow and operator handlingDesigned for coordinated bottle-line arrangements
Primary selection questionHow many pieces with acceptable operator process?How many finished bottles per minute are required?
Selection tip: Do not compare 3,000 pieces/min directly with 40 bottles/min. The number of pieces in each bottle must be considered.
PRACTICAL BUYING GUIDE

How to Choose a Capsule or Tablet Counting Machine

The most useful quotation begins with your actual product and packaging requirements, not only a preferred model number.

01

Identify the Product

Provide hard capsule size, softgel dimensions or tablet shape. Irregular shapes and fragile products may need specific testing.

02

Define Count per Bottle

Specify the required quantity, such as 30, 60, 100 or 500 pieces per bottle. This changes achievable bottle output.

03

Set the Bottle Output

State your target bottles per minute or per shift, including realistic allowance for stops and changeovers.

04

Check Bottle Dimensions

Share bottle shape, capacity, height and opening diameter. A 10–500ml specification alone does not guarantee fit.

05

Plan the Packaging Line

Determine whether you need bottle unscrambling, desiccant insertion, capping, sealing or labeling.

06

Agree on Testing

To confirm counting accuracy, practical speed and bottle handling will be checked with representative samples.

Not sure which model to choose?

Send product photos, dimensions, count per bottle, target bottles per minute and bottle drawings. We can discuss a suitable URGC configuration.

Send Your Counting Requirements →
PRODUCTION CAPACITY EXPLAINED

Pieces per Minute vs. Bottles per Minute: How Much Output Do You Actually Need?

A counter's piece-counting rate and a packaging line's bottle output describe different things. A semi-automatic machine rated at 2,000 pieces/minute is not necessarily capable of filling 2,000 bottles/minute. Bottle output depends on the number of products per bottle and time spent positioning, discharging and exchanging containers.

First-pass theoretical estimate

Bottles/min ≈ Counting rate (pieces/min) ÷ Count per bottle

This is an upper-bound calculation before bottle handling, feeding interruption, rejects, product changeovers and other production losses. It is not a guaranteed operating speed.

Illustrative counting rateCount / bottleTheoretical upper boundWhat still needs checking
2,000 pcs/min3066.6 bottles/minBottle handling and discharge
2,000 pcs/min6033.3 bottles/minFeeding stability and indexing
2,000 pcs/min10020 bottles/minActual tested production speed
2,000 pcs/min20010 bottles/minDownstream packaging line balance

Examples are mathematical illustrations, not measured representative output. Automatic URGC-S model ratings are separately published in bottles/minute under the supplied model specifications.

Four Inputs Needed to Size Your Counting Line

Product

Capsule size, tablet diameter, coating, fragility and flow behavior.

Pack Count

Number of finished units in each bottle, including different SKU recipes.

Bottle

Material, shape, neck opening and overall height.

Output Target

Good bottles per minute or per shift at the agreed acceptance criteria.

Need a capacity recommendation rather than a brochure maximum?

Send the count per bottle, product sample details and target bottles per minute. Ask for a test based on your actual combination, not an unrelated demonstration.

Request a Capacity Assessment →
MEASUREMENT AND VALIDATION

Counting Accuracy & Sample Testing

Brochures may use terms such as accuracy, error percentage or incorrect bottles per thousand. These are not interchangeable without a defined measurement method. For procurement, agree on the denominator, sample size, acceptable deviation and test conditions before accepting a performance claim.

Piece-Count Error

Compares the actual number of capsules or tablets in a bottle with the target count. A one-piece shortfall in a 100-count bottle is different from a bottle-level pass/fail metric.

Bottle-Level Error Rate

Counts how many inspected bottles fail the agreed quantity requirement. The result depends on the sample size, pass/fail definition and production conditions.

Practical Acceptance-Test Procedure

1. Agree on product and bottle samples
2. Set the target count and operating speed
3. Collect a defined bottle sample
4. Independently verify and record results

Run the test with representative capsules or tablets, including the dust and handling conditions expected during production. Record short counts, overcounts, jams, damaged products and sustained bottle throughput. Repeat after a changeover if your line handles multiple SKUs.

Specification clarification: The supplied URGC-6BS brochure states >99.5%, URGC-2B states ±0.3%, and the URGC-S sheet uses a bottle-level error expression of ≤2‰. These should remain brochure claims until the supplier confirms how each is measured. Do not market them as guaranteed error-free operation.
URGC-8S Automatic Counter Testing and Quality Inspection Setup

Application Case Studies and Project Evidence

Use actual customer-approved installations, workshop test records or documented projects. The two blocks below are publication templates and do not claim completed customer projects.

URGC-6BS Semi-Automatic Capsule Bottle Counting Project Setup
PROJECT DOCUMENTATION TEMPLATE — NOT A PUBLISHED CUSTOMER CASE

Capsule Bottle Counting Project

ProductInsert verified capsule type and size
Count per bottleInsert confirmed quantity
MachineURGC-6BS Operator-Assisted Counter
ResultInsert measured and approved test outcome

Publish only after replacing all placeholders with verified project information.

URGC-2B Tablet Counting and Packaging Project Setup
PROJECT DOCUMENTATION TEMPLATE — NOT A PUBLISHED CUSTOMER CASE

Tablet Bottle Packaging Line

ProductInsert verified tablet specification
PackagingInsert bottle and cap details
EquipmentURGC-2B Dual-Head Counter Configuration
ResultInsert measured and approved project outcome

Do not publish customer names, countries or results without evidence and permission.

HOW ELECTRONIC COUNTING WORKS

How Does an Automatic Capsule Counting Machine Work?

A typical electronic counting process moves products from a hopper through feeding channels to a sensor-controlled discharge system.

01

Product Loading

Capsules or tablets are placed into the hopper. Material condition and cleanliness affect subsequent feeding.

02

Vibration Feeding

Vibrating tracks move products forward and help create a suitable flow toward the counting channels.

03

Product Separation

Products are guided to reduce overlapping or irregular flow before detection.

04

Electronic Detection

Photoelectric sensors detect passing products and send count signals to the controller.

05

Preset-Quantity Discharge

The controller coordinates discharge after the target count is reached, according to the machine configuration.

06

Bottle Transfer

The filled bottle proceeds to the next station and the counting cycle continues.

Why is the counting principle important when buying a machine?

A counter must reliably separate and detect your actual products at the required production speed. A brochure output figure does not replace a test using your capsule or tablet samples.

See the Testing Checklist →
Live Demonstration

Operation Video: Capsule Counting Machine for Tablets, Pills & Softgels

CLARIFYING THE PROCESS

Counting, Capsule Filling and Bottle Filling: Three Different Operations

A capsule counting machine does not manufacture capsules or fill powder into empty capsule shells. Its job begins after finished capsules or tablets are available for packaging. It detects individual solid-dose units, accumulates a preset quantity and dispenses that quantity into a container.

Capsule Filling Machine

Fills empty hard capsule shells with powder, pellets or other compatible formulations. This is an upstream production operation.

See capsule filling equipment →

Electronic Counting Machine

Counts finished capsules or tablets into bottles. The critical variables are product separation, sensor detection, count per bottle and discharge performance.

Compare counting equipment →

Complete Bottle Packaging Line

Combines bottle feeding, counting, optional desiccant insertion, capping, sealing and labeling. Throughput is limited by the slowest coordinated operation.

Explore line configuration →
For buyers: If your project involves filling empty capsules, request capsule filling equipment. If it involves packing 30, 60 or 100 finished capsules into bottles, request an electronic counter. If you need a fully ready bottle, ask for an integrated packaging line.
PRODUCT COMPATIBILITY

What Products Can a Capsule and Tablet Counter Handle?

Hard Capsules

Capsule orientation, shell dimensions and product flow should be confirmed. The supplied URGC-S sheet lists #0–#5 applications.

Plain Tablets

Round, oval or flat tablet shapes may behave differently on vibration tracks. Confirm the actual product dimensions.

Coated Tablets

Surface characteristics, dust and potential damage should be considered during sample testing.

Softgel Capsules

Softgels may have different friction and handling behavior. Confirm compatibility rather than assuming every shape works.

Pills and Supplements

Pills outside standard tablet shape and physical condition are candidates for regular product trials.

Plastic Bottles

The supplied semi-automatic sheets specify selected round or square plastic bottles of 10–500 ml. Confirm neck opening and dimensions.

Common Counting Problems and Their Causes

Observed ProblemPossible Cause to InvestigateRecommended Check
Under countsVariable dust accumulation on detectorsPrevent dust with sensors and check product condition
Double countsOverlapping product or poor track settingsOptimize track spacing and detection speed
Product jamsUnsuitable feed tracks or damaged product unitsInspect channels and test product flow
Bottle neck spillsIncorrect funnel timing or narrow neckReview delivery funnel and bottle dampers
Lower-than-expected outputHigh bottle counts or slow bottle transferCheck each operation in the continuous line

Cleaning and Routine Maintenance

Establish product-specific cleaning procedures and follow the machine manual. Regularly inspect product-contact surfaces, feeding tracks, sensor windows and discharge areas. When changing products, confirm that previous product residue has been removed and that the selected counting settings are appropriate. Site validation and regulatory requirements remain the responsibility of the operating facility.

MACHINE ANATOMY

Key Components of an Electronic Counting Machine

Understanding the product path makes it easier to evaluate counting accuracy, reliability and changeover access. The following description fits typical brochure setups and should remain subject to confirmed layout drawings for the selected URGC model.

01 • Feeding

Product Hopper & Feed Regulation

Holds incoming capsules or tablets and directs them to the feeding sections. Uneven product pressure or irregular feeding can affect separation.

02 • Separation

Vibratory Channels

Guides products along multiple lanes. Channel geometry, vibration settings and product condition determine whether units travel separately.

03 • Detection

Electronic Counting Sensors

Detect passing products and send count signals to the controller. Dust, product velocity and sensor contamination should be considered during testing.

04 • Control

Controller & Count Settings

Tracks the programmed quantity and coordinates the counting cycle. Confirm the operating interface, recipe functions and alarm behavior for the actual configuration.

05 • Discharge

Gate, Funnel & Bottle Positioning

Directs the counted products into container necks. Opening speed, funnel alignment and bottle positioning can limit filling capacity.

06 • Hygiene

Contact Surfaces & Cleaning Access

Check which surfaces contact the product, their verified metal grades, and how the feeding tracks and discharge components are accessed for cleaning.

Request the configuration drawing before ordering.

Ask for a product-contact material list, machine footprint, utility requirements and the cleaning procedure for your exact model.

Ask for Technical Details →
COMPLETE PACKAGING SOLUTIONS

Capsule and Tablet Counting Line Configuration

The counting machine is one station in a bottle packaging process. Line configuration depends on the product, container and required packaging operations.

01

Bottle Unscrambling

Supplies oriented empty bottles to the conveyor.

02

Electronic Counting

Counts the preset quantity into positioned bottles.

03

Desiccant Insertion

Optional station when moisture-protected packaging includes a desiccant.

04

Capping

Applies compatible closures after filling.

05

Induction Sealing

Optional sealing step based on bottle and closure design.

SUPPLIER EVALUATION

What Should You Check Before Ordering a Counting Machine?

Beyond headline speed, a buyer should confirm testing, documentation, machine configuration and after-sales arrangements.

Technical Review

Request an approved specification sheet for the exact model, including power, size, product range and machine configuration.

Sample Verification

Agree on representative product tests and the method used to check counts and throughput.

Factory Acceptance

Define the inspection checklist, demonstration evidence and responsibilities before shipment.

Documentation

Confirm manuals, drawings, material declarations and other documents required for your market and facility.

Installation Planning

Check utilities, line interfaces, operator access and training arrangements.

Service Terms

Confirm warranty scope, spare parts availability and support channels in the final quotation.

BUYER QUESTIONS

Capsule and Tablet Counting Machine FAQs

▼ Can one machine count both tablets and capsules?

Selected URGC models are described for compatible capsules and tablets. Confirm your specific product dimensions and handling characteristics with a sample test.

▼ What is the difference between electronic counting and counting by weight?

Electronic counting detects individual pieces passing through a sensor system. Weight-based estimation uses mass and average piece weight; variations in individual weight can affect the estimated quantity. The appropriate method depends on the product and accuracy requirements.

▼ How many bottles per minute can a counting machine fill?

The URGC-S brochure lists nominal ranges from 10–40 bottles/min for URGC-8S up to 10–120 bottles/min for URGC-48S. Actual output depends on product characteristics, count per bottle and line conditions.

▼ Can I change the number of tablets or capsules in each bottle?

The supplied URGC-S sheet lists an adjustable count setting of 2–9999 per bottle. Confirm the achievable speed and compatibility for your intended count.

▼ How should counting accuracy be checked?

Agree on the test product, preset count, speed, number of sampled bottles and how incorrect counts are defined. Different published error figures should not be compared without the same test method.

▼ Can a counter handle dusty or fragile tablets?

Suitability depends on feeding behavior, product integrity and detection performance. Submit representative samples for assessment and discuss dust management and handling requirements.

▼ What affects the price of a counting machine?

Machine capacity, automation level, product-handling requirements, bottle format, customization, line integration, documentation and support arrangements can all affect the quotation.

▼ What should I provide to request a quotation?

Send the product type and dimensions, count per bottle, bottle drawings or samples, target bottles/minute, destination country and any required downstream packaging equipment.

Contact information

Email

venti@urmachine.com

Tel

+86 17365104069

Address

No. 163 Wangjiang Street, Dongshan Subdistrict, Ruian City, Wenzhou City, Zhejiang Province, China

Working Hours

Monday to Friday: 9:00 - 18:00

Send us A Message

en_USEnglish

Request a Quote

  • For project inquiries or technical drawings, please email us at venti@urmachine.com.
  • We will contact you within 1 working day